Model Number: Approved, Classic 6 degree, Veritcal 1 Degree and Vertical 3 degree.
APL Number: 548-000-029
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Segmental Block FDOT Wall Type 4A and 4B (Permanent). See Specification Section 548 and Structures Design Guidelines Section 3.12-C
Use AASHTO default values for pullout friction factor F*, and a scale correction factor alpha of 0.8. To be used with StrataGrid reinforcement.
Model Number:
APL Number: 548-000-003
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C, 2D, 2E, and 2F (Permanent)
Model Number:
APL Number: 548-000-013
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C and 2D (Permanent) || Maximum spacing for transverse reinforcement bars = 24 Inches.
Model Number:
APL Number: 548-000-027
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Segmental Block FDOT wall type 4A and 4B (Permanent). See Specification Section 548 and Structures Design Guidelines Section 3.12-C || Use AASHTO default values for pullout friction factor F*, and a scale correction factor "alpha" of 0.8. To be used with TenCate Miragrid 3XT, 5XT, and 8XT only.
Forix
(APL Product)
Model Number:
APL Number: 548-000-033
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: Approved for wall types 1A, 1B, 1C, and 1D. (Permanent). Maximum wall height for roadway support is 12 feet.
Model Number:
APL Number: 548-000-011
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Gravix
(APL Product)
Model Number:
APL Number: 548-000-025
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: Approved for wall types 1A, 1B, 1C, 1D and 1E. (Permanent)
Model Number:
APL Number: 548-000-026
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Segmental Block FDOT wall type 4A and 4B (Permanent). See Specification Section 548 and Structures Design Guidelines Section 3.12-C. || Use AASHTO default values for pullout friction factor F*, and a scale correction factor "alpha" of 0.8. To be used with TenCate Miragrid 3XT, 5XT, 7XT, 8XT, 10XT or StrataGrid SGU60, SGU80 or SGU120.
Model Number: MagnumStone Gravity Wall
APL Number: 548-000-034
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Maximum exposed height of 5 feet. || Segmental Block wall for use in Gravity Wall applications.
Model Number:
APL Number: 548-000-012
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C and 2D (Permanent)
Model Number:
APL Number: 548-000-022
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary) || Limited to 5 year Service Life ONLY
OPTIMA
(APL Product)
Model Number:
APL Number: 548-000-035
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Not Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan.
Comment: FDOT Wall Type 2A, 2B, 2C, 2D (Permanent)
Fabrication:
Multiple Materials used for Product Type, Classify each product separately
Model Number:
APL Number: 548-000-002
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-018
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Types 2A,2B, 2C, 2D, 2E and 2F (Permanent)
Model Number:
APL Number: 548-000-015
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C and 2D Using "HA Ladder" soil reinforcements Only (Permanent)
Model Number:
APL Number: 548-000-014
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C and 2D Using "HA Ribbed Strip" soil reinforcements Only (Permanent)
Model Number: EarthTrac
APL Number: 548-000-032
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Types 2A, 2B, 2C and 2D (Permanent)
Model Number:
APL Number: 548-000-017
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: Drawings are currently under revision. Please contact Product Evaluation prior to use. || FDOT Wall Types 2A,2B, 2C and 2D (Permanent) || FDOT Wall Types 2A,2B,2C and 2D (Permanent. Verify strip thickness at every level during construction.
Model Number:
APL Number: 548-000-031
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Types 2A, 2B, 2C and 2D (Permanent) || Maximum spacing for transverse reinforcement bars = 12 Inches.
Model Number:
APL Number: 548-000-030
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Modular Block Wall, allowed for Gravity Wall type applications
Model Number:
APL Number: 548-000-019
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Fabrication:
Buy America Category: Manufactured Product - Exempt Incidental
Model Number: Type III
APL Number: 548-000-023
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary) Pullout resistance calculations shall be performed using AASHTO default values (F* and alpha). System approved for use with Synteen SF20, SF35, SF55, and SF80 geogrid.
Model Number:
APL Number: 548-000-004
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-006
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-007
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-028
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Satisfies requirements for two-phased MSE Retaining Wall. || Use with UX1400, UX1500, UX1600, or UX1700 Geogrid only.
Model Number:
APL Number: 548-000-021
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-020
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: A reduction factor for installation damage of geosynthetic reinforcement of 1.5 shall be applied when using coarse aggregate as backfill. || FDOT Wall Types 2A,2B, 2C and 2D (Permanent) with Metallic Connectors, 2A, 2B, 2C, 2D, 2E and 2F (Permanent) with Geosynthetic Connector. Internal stability check for pull-out shall make use of AASHTO default values.
Model Number: Formerly The Neel Co
APL Number: 548-000-016
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Types 1A,1B, 1C and 1D (Permanent)
Model Number: Approved, Classic 6 degree, Veritcal 1 Degree and Vertical 3 degree.
APL Number: 548-000-029
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Segmental Block FDOT Wall Type 4A and 4B (Permanent). See Specification Section 548 and Structures Design Guidelines Section 3.12-C
Use AASHTO default values for pullout friction factor F*, and a scale correction factor alpha of 0.8. To be used with StrataGrid reinforcement.
Model Number:
APL Number: 548-000-003
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C, 2D, 2E, and 2F (Permanent)
Model Number:
APL Number: 548-000-013
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C and 2D (Permanent) || Maximum spacing for transverse reinforcement bars = 24 Inches.
Model Number:
APL Number: 548-000-027
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Segmental Block FDOT wall type 4A and 4B (Permanent). See Specification Section 548 and Structures Design Guidelines Section 3.12-C || Use AASHTO default values for pullout friction factor F*, and a scale correction factor "alpha" of 0.8. To be used with TenCate Miragrid 3XT, 5XT, and 8XT only.
Forix
(APL Product)
Model Number:
APL Number: 548-000-033
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: Approved for wall types 1A, 1B, 1C, and 1D. (Permanent). Maximum wall height for roadway support is 12 feet.
Model Number:
APL Number: 548-000-011
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Gravix
(APL Product)
Model Number:
APL Number: 548-000-025
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: Approved for wall types 1A, 1B, 1C, 1D and 1E. (Permanent)
Model Number:
APL Number: 548-000-026
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Segmental Block FDOT wall type 4A and 4B (Permanent). See Specification Section 548 and Structures Design Guidelines Section 3.12-C. || Use AASHTO default values for pullout friction factor F*, and a scale correction factor "alpha" of 0.8. To be used with TenCate Miragrid 3XT, 5XT, 7XT, 8XT, 10XT or StrataGrid SGU60, SGU80 or SGU120.
Model Number: MagnumStone Gravity Wall
APL Number: 548-000-034
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Maximum exposed height of 5 feet. || Segmental Block wall for use in Gravity Wall applications.
Model Number:
APL Number: 548-000-012
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C and 2D (Permanent)
Model Number:
APL Number: 548-000-022
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary) || Limited to 5 year Service Life ONLY
OPTIMA
(APL Product)
Model Number:
APL Number: 548-000-035
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Not Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan.
Comment: FDOT Wall Type 2A, 2B, 2C, 2D (Permanent)
Model Number:
APL Number: 548-000-002
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-018
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Types 2A,2B, 2C, 2D, 2E and 2F (Permanent)
Model Number:
APL Number: 548-000-015
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C and 2D Using "HA Ladder" soil reinforcements Only (Permanent)
Model Number:
APL Number: 548-000-014
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 2A, 2B, 2C and 2D Using "HA Ribbed Strip" soil reinforcements Only (Permanent)
Model Number: EarthTrac
APL Number: 548-000-032
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Types 2A, 2B, 2C and 2D (Permanent)
Model Number:
APL Number: 548-000-017
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: Drawings are currently under revision. Please contact Product Evaluation prior to use. || FDOT Wall Types 2A,2B, 2C and 2D (Permanent) || FDOT Wall Types 2A,2B,2C and 2D (Permanent. Verify strip thickness at every level during construction.
Model Number:
APL Number: 548-000-031
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Types 2A, 2B, 2C and 2D (Permanent) || Maximum spacing for transverse reinforcement bars = 12 Inches.
Model Number:
APL Number: 548-000-030
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Modular Block Wall, allowed for Gravity Wall type applications
Model Number:
APL Number: 548-000-019
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number: Type III
APL Number: 548-000-023
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary) Pullout resistance calculations shall be performed using AASHTO default values (F* and alpha). System approved for use with Synteen SF20, SF35, SF55, and SF80 geogrid.
Model Number:
APL Number: 548-000-004
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-006
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-007
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-028
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Comment: Satisfies requirements for two-phased MSE Retaining Wall. || Use with UX1400, UX1500, UX1600, or UX1700 Geogrid only.
Model Number:
APL Number: 548-000-021
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Type 3 (Temporary)
Model Number:
APL Number: 548-000-020
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: A reduction factor for installation damage of geosynthetic reinforcement of 1.5 shall be applied when using coarse aggregate as backfill. || FDOT Wall Types 2A,2B, 2C and 2D (Permanent) with Metallic Connectors, 2A, 2B, 2C, 2D, 2E and 2F (Permanent) with Geosynthetic Connector. Internal stability check for pull-out shall make use of AASHTO default values.
Model Number: Formerly The Neel Co
APL Number: 548-000-016
Specification: Retaining Wall Systems
Product Type: Retaining Wall System
BABA Eligible: Eligible
Limitation:
Must be provided from a Qualified Producer with current QC Plan
Comment: FDOT Wall Types 1A,1B, 1C and 1D (Permanent)